Similar For Fieldpiece User Manuals |
---|
More Fieldpiece User Manual |
---|
# | Title | Type | Language | Download |
1. |
Opman SC76 v16.qxd - Fieldpiece Instruments
AUTO RANGING DIGITAL CLAMP METER Model SC76 Works with Fieldpiece accessory heads Fieldpiece ER HIV WARNING NON CONTACT VOLTAGE AUTO POWER OFF CAT I COM W 6 6 WAA Fieldpiece ONLI OPERATOR S MANUAL Works with Fieldpiece accessory heads Connect your Fieldpiece accessory head to SC series meter through included deluxe silicone leads Use 340mVDC or 3400mVDC range for most heads a |
PDF Manual |
ENGLISH |
|
2. |
SMAN360 - Fieldpiece Instruments
Fieldpiece Digital Manifold amp Micron Gauge OPERATOR S MANUAL Model SMAN360 PAA Ae pa RARA pia 888 HABE GHEE page GEOG Controls SL I T LLT nf 3 A i 1 Ce A Refrigerant Y a 1 N s I CAL CAL l eu 2 a rp 2 A W ho Nn WN 7 8 9 10 11 12 3 Fieldpiece C7 Insert Type K thermocouple plugs here Temperature calibration pots 14 Press to zero atmospheric pressure Press to calibrate to refrigerant |
PDF Manual |
ENGLISH |
|
3. |
Presión - Fieldpiece Instruments
Fielapiece Manifold Digital MANUAL DEL OPERADOR Modelo SMAN320 Controles SLT S am 4 a a 5 A 1 E de pal T Aici Al 2 CAL s E C3 Fieldpiece ETE A gt 1 Inserte aqu los tapones de termopar tipo K Potenci metros de calibraci n de temperatura Pulse para llevar a cero la presi n atmosf ricaz2 Pulse para calibrar el dep sito de refrigerante Vea la secci n Calibraci n avanzada de la presi n Pulse para confirmar la sel |
PDF Manual |
ENGLISH |
|
4. |
Opman AVG2 v09.qxd - Fieldpiece Instruments
Vacuum Gauge Accessory Head Model AVG2 VAA Fieldpiece aver _ VAA Fieldpi ce LEO NLL OPERATOR S MANUAL Specifications Sensor Precision thermistor Fitting Standard 1 4 flared brass fitting male Conversion rate 1 mVDC 1 micron of mercury Range 50 to 2000 microns of mercury Resolution 1 micron of mercury Accuracy 10 or 10 microns 50 to 1000 microns 73 F 9 F 23 C 5 C lt 90 RH Operating environment 32 to |
PDF Manual |
ENGLISH |
|
5. |
Presión - Fieldpiece Instruments
Fieldpiece Man metro de vac o y colector digital MANUAL DEL OPERADOR Modelos SMAN2 SMAN3 A w N vo 0 N QAQ 10 f pja n Pl J 000 ds Bab AHH oA Inserte termocuplas tipo K con enchufes machos aqu Recipientes de calibraci n de temperatura Presione hasta la presi n atmosf rica cero Presione hasta la curva de presi n con ajuste lineal Consulte la secci n Calibraci n avanzada de presi n Presione para que aparezca la retroil |
PDF Manual |
ENGLISH |
|
6. |
Opman ASX14 v07.qxd - Fieldpiece Instruments
Superheat and Subcooling Head for R22 and R410A with pipe clamp thermocouple Model ASX14 Air Conditioner Superheat and Subcooling 28T O Roz sh ENGLISH HOA SC Ra mi SH or SC mq Temp Pressure m OFF i Tie fo amo ca AUTO VETA Fieldpiece T ASRI Fieldpiece LO NLL OPERATOR S MANUAL SPECIFICATIONS Operating environment 32 F to 122 F 0 C to 50 C at lt 75 RH Allow 5 min |
PDF Manual |
ENGLISH |
|
7. |
HG1 & HG2 - Fieldpiece Instruments
12 HVAC GUIDE i7 Uif g a 4 GUIDED PROBE TESTER 2 re inn 6 m WA T 2 ui ro rs oe 9 ae _ F PF rT HVAC GUIDE Tester Table of Contents Field Manual ae HG1 8 HG2 Table of Content ta HVAC Guide Tester Controls 4 ate Select the Test Switch Positions 6 Do it right the first time Fill in |
PDF Manual |
ENGLISH |
|
8. |
SDMN6 - Fieldpiece Instruments
Fielapiece Dual Port Manometer and Pressure Switch Tester OPERATOR S MANUAL Model SDMN6 Manometer and Pressure Switch Tester we ie a Specifications Operating environment 32 F to 118 F 0 C to 48 C at lt 80 RH Storage temperature 4 F to 140 F 20 C to 60 C 0 to 80 RH with battery removed Power 9V NEDA 1604A IEC 6LR61 9V alkaline battery Battery life alkaline 200 hours manometer only backlight off 12 hours pressu |
PDF Manual |
ENGLISH |
|
9. |
Fieldpiece LT17AW EH4W - Fieldpiece Instruments
Fielapiece Wireless Digital Multimeter MAXMIN HOLD a ull OPERATOR S oi OLD a a MANUAL HAE oy WIRELESS ENABLED Model LT17AW Fieldpiece ay ED LTIZAW o e 15 SEC FOR 500MV e RANGE X ma CAT III MA 600V5 fi FUSED 200MA MAX UNPLUG TEST LEADS A E 30V TYPEK MAX Specifications Wireless range Up to 75 feet 23m line of sight Minimum Wireless Distance Up to 1 foot 30cm Wireless Frequency 910MHz to 920MHz US 868 |
PDF Manual |
ENGLISH |
|
10. |
Fieldpiece - Allied Supply
Fieldpiece Digital Manifold amp Vacuum Gauge OPERATOR S MANUAL Models SMAN2 SMAN3 1 Insert K type thermocouple plugs here 2 Temperature calibration pots 3 Press to zero atmospheric pressure 4 Presstolinear adjust pressure curve See Advanced Pressure Calibration section Press to engage backlight Hold when powering on to toggle Auto Power Off Press hold to cycle through refrigerants Hold 1 second to toggle power on off Press up o |
PDF Manual |
ENGLISH |
|
11. |
User Manuals - Fieldpiece Instruments
Fieldpiece Essential Clamp Meters OPERATOR S Fietdpiece MANUAL Models SC440 SC420 Safety Information Never ground yourself when taking electrical measurements Do not touch exposed metal pipes outlets fixtures etc which might be at ground potential while taking measure ments Keep your body isolated from ground by using dry clothing rubber shoes rubber mats or any approved insulating material Disconnect the t |
PDF Manual |
ENGLISH |
|
12. |
SC55 - Fieldpiece Instruments
Fielapiece OPERATOR S MANUAL Models SC55 SC56 Safety Information e Never ground yourself when taking electrical measurements Do not touch exposed metal pipes outlets fixtures etc which might be at ground potential while taking measure ments Keep your body isolated from ground by using dry clothing rubber shoes rubber mats or any approved insulating material e Disconnect the test leads before opening the case Inspect the test leads for damage to t |
PDF Manual |
ENGLISH |
|
13. |
Opman SRL2 v29.qxd - Fieldpiece Instruments
D tecteur infrarouge de fuites de r frig rant Mod le SRL2 PRESS FOR 1 SECOND Refrigerant Leak Detector t Fieldpiece LT UT MANUEL D UTILISATION Utilisation Protection ON OFF Pour allumer ou teindre le SRL2 appuyez et main tenez appuy le bouton ON OFF pendant une seconde Ce l ger d lai permet d viter d appuyer sur le bouton par inadvertance Si vous oubliez de l teindre le SRL2 s teint automatiquement au bout de 10 minutes Affic |
PDF Manual |
ENGLISH |
|
14. |
Opman HS26 v214.qxd - Fieldpiece Instruments
THE ORIGINAL STICK METER MODEL HS26 _ _ he Fieldpiece LAO NLD OPERATOR S MANUAL SPECIFICATIONS Display 3 digit liquid crystal display LCD with a maximum reading of 1999 Overrange OL mark indication Auto power off approx 60 minutes Operating environment 32 to 122 F 0 to 50 C at lt 70 R H Storage temperature 4 to 140 F 20 to 60 C 0 to 80 R H with battery removed Accuracy Specifications good in ambient condi tions of 73 F |
PDF Manual |
ENGLISH |
|
15. |
User Manuals - Fieldpiece Instruments
Fieldpiece Compact Clamp Meters OPERATOR S MANUAL Models SC260 C240 SC220 O paue aa ES E SC260 f SCAN HOLD MAXMIN IN Soon IEnREN mka YA CE A AUTO OFF gi TYPE K i gov C N gi TEMP aX l Safety Information Never ground yourself when taking electrical measurements Do not touch exposed metal pipes outlets fixtures etc which might be at ground po |
PDF Manual |
ENGLISH |
|
16. |
Opman LT83A v16.qxd - Fieldpiece Instruments
DIGITAL MULTIMETER Model LT83A MAX MIN HOLD 088 Bie kHz MHz Fieldpiece LT83A AUTO POWER OFF CATI FUSED aX TOAGOSEC 15SEC FOR 200MV RANGE 10A VA Fieldpiece LO NLS OPERATOR S MANUAL General specifications Auto off off after 25 minutes to extend battery Indicators Continuity beeper lt 100Q Low bat Overrange OL or OL is displayed Operating environment 32 F to 122 F lt 70 RH Storage environment w |
PDF Manual |
ENGLISH |
|
17. |
Opman AAV3 v06.qxd - Fieldpiece Instruments
Fieldpiece Accesorio expansor para velocidad del aire y temperatura del aire Modelo AAV3 pra 5 a MANUAL DEL OPERADOR Flujo volum trico No hay sustituto a la utilizaci n de una campana para medir el flujo volum trico pie c bico por min uto o L s El AAV3 puede sin embargo ser usado para estimar el flujo volum trico El flujo volum tri co iguala la velocidad del aire en pies minuto o metros segundo multiplicada por el rea libre e |
PDF Manual |
ENGLISH |
|
18. |
Opman SRL8 v15.qxd - Fieldpiece Instruments
Heated Diode Refrigerant Leak Detector Model SRL8 BATTERY PRESS FOR CHECK Heated Diode Refrigerant Leak Detector _ wan Fieldpiece hee LLY OPERATOR S MANUAL Leak Detection Procedure Keep the SRL8 away from any areas of potential refrigerant leakage until the warm up and calibration period is over The warm up and calibration sequence lasts about 30 seconds after ON OFF is pressed Allow the SRL8 to fully warm up before using On startup |
PDF Manual |
ENGLISH |
|
19. |
Opman ST4 v07.qxd - Fieldpiece Instruments
Fieldpiece Dual Temperature Digital Thermometer Model ST4 ee iA Fieldpiece _ VAA Fieldpiece LAO NLL OPERATOR S MANUAL Specifications Measurement range 58 to 2000 F 50 to 1300 C Resolution 0 1 Temperature coefficient 0 1 x specified accura cy per C 0 to 18 C 28 to 50 C System accuracy after field calibration 1 F 30 to 120 F with field calibration 0 5 C 0 to 50 C with field calibration Meter accuracy Accura |
PDF Manual |
ENGLISH |
|
20. |
SPK3 - Fieldpiece Instruments
IR and Rod Thermometer Model SPK3 with Laser Take temps in close or at range Point the laser for 8 1 IR infrared temperatures or push the rod through ducts for dry bulb air temperatures T1 T2 mode works across both IR and Rod modes Features E Use for walk around or in duct checks E Max min Hold and T1 T2 functions E Hangs from duct walls or air register fins E Sharp narrow tip for insertion into duct work E Display flips IR ROD for easy viewing E Clips |
PDF Manual |
ENGLISH |
|