Similar For Dwyer User Manuals |
---|
More Dwyer User Manual |
---|
# | Title | Type | Language | Download |
1. |
Software - Dwyer Instruments, Inc.
Instruction Manual PUX2 PC LOADER SOFTWARE INSTRUCTION MANUAL Dwyer Instruments Inc Bulletin F 9 PUX2 S Bulletin F 9 PUX2 S Contents 1 OUTLINE www Win we pu Ed a SE Siw 1 1 1 COPYRIGHT OF THIS SOFTWARE X TE 1 1 2 GENERAL |
PDF Manual |
ENGLISH |
|
2. |
DWYER INSTRUMENTS, INC. Phone: 219/879-8000
Bulletin T 10 IR2 Series IR2 Infrared Non Contact Thermometer Dwyer The Series IR2 Infrared Temperature Thermometer allows users to economically take accurate measurements in hard to reach areas Measurements can be taken at a safe distance with a 12 1 Distance to Target Ratio The IR2 easily takes measure ments within 2 accuracy using a built in laser sighting The fixed emissivity of 0 95 is perfect for measuring surface temperatures of concrete asphalt rubber o |
PDF Manual |
ENGLISH |
|
3. |
666iom (Page 1) - Dwyer Instruments, Inc.
BULLETIN A 30 666 SERIES 666 RANGEABLE DIFFERENTIAL PRESSURE TRANSMITTER Specifications Installation and Operating Instructions 3 16 4 76 DIA MOUNTING HOLE es lt 19 05 6 13 64 157 56 5 19 32 3 16 4 76 OD PRESSURE FITTING 142 08 Description Versatility is the key with our Series 666 Rangeable Differential Pressure Transmitter Up to 6 field selectable pressure ranges are available in a single model Four dipswitches located |
PDF Manual |
ENGLISH |
|
4. |
DWYER INSTRUMENTS, INC. Phone: 219/879-8000
The Model OSW 100 Wall Mount Occupancy Sensor is an infrared sensor designed to automatically control a HVAC ventilation system A unique dual delay processor eliminates false triggers due to short term occupancies The Model OSW 100 has a wide 110 viewing angle to capture movement up to 49 2 ft 15 m away INSTALLATION OQ Do not install where the detector is exposed to direct Sunlight or directly above strong sources of heat S Do not install in areas that have any ob |
PDF Manual |
ENGLISH |
|
5. |
LOVE CONTROLS DIVISION - Dwyer Instruments, Inc.
LED LOYE Monitor and control temperature in heating and cooling applications with the Series TCS Thermocouple Switch The Series TCS offers a wide temperature range two selectable alarm sets and an internal buzzer indicating alarm condition or error The user can define set point heating cooling regulation cycle time alarm configuration load status and ambient probe adjustment The thermocouple switch features pass word protection and error alarm messaging Te |
PDF Manual |
ENGLISH |
|
6. |
DWYER INSTRUMENTS, INC.
Model HP Hand Pump Bulletin TE HP The Model HP Hand Pump provides a dual source of pneumatic pressure and vacuum for verifying the calibration of pressure instrumentation Pump can generate pressures up to 45 psi 3 bar and vacuum to 27 Hg 910 mbar The compact pump is designed for portability and single hand operation Model HP features a pressure relief valve and fine adjustment for control better than 0 0015 psi 0 1 mbar Pump includes two 39 1 m hoses |
PDF Manual |
ENGLISH |
|
7. |
DMF - Dwyer Instruments, Inc.
Technical Data Sheet No TD9805M Rev L Date of issue September 2006 OPERATING MANUAL FOR DMF DIGITAL MASS FLOW CONTROLLERS DIGITAL MASS FLOW CONTROLLER SERIES P O Box 373 Michigan City IN 46361 USA Phone 219 879 8000 E mail info dwyer com FAX 219 879 9057 Internet http www dwyer inst com TABLE OF CONTENTS 1 UNPACKING THE DMF MASS FLOW CONTROLLER 1 1 1 Inspect Package for External |
PDF Manual |
ENGLISH |
|
8. |
LOVE CONTROLS DIVISION - Dwyer Instruments, Inc.
L A LOYE 1 3 8 35 08 The Series TSX3 Digital Temperature Switch was designed to control the compressor fan and defrost in refrigeration applications This generation of controls has field selectable engineering units and input temperature types in order to reduce the combination of parts that need to be stocked A built in real time clock is used for HACCP logging of temperature alarms caused by temperatures out of their set limits or loss of power The Intellig |
PDF Manual |
ENGLISH |
|
9. |
IP - Dwyer Instruments, Inc.
Dwyer Instruments Inc Michigan City IND 46361 Phone 219 879 8868 Fax 219 872 9057 The Series IP I P Current to Pressure Transducer a RENN NN g Yi L I AG Installation Operation and Maintenance Instructions N RY ANSASSA UL N z Pilot Pressure pj Supply Pressure Atmospheric Pressure E Output Pressure Contents Section Description Page 1 0 Description amp In |
PDF Manual |
ENGLISH |
|
10. |
DWYER INSTRUMENTS, INC. Phone: 219/879-8000
Bulletin V 12 Series 3ABV Automated Ball Valves 3 Way Brass NPT Specifications Installation and Operating Instructions pC ETRCINMGEN rete Weds a te be 5 5D 6B 6H 65 7 GA 84 amp 40 40 40 40 45 46 45 4D 2644 264 264 3B 3B 4B 4 55 5 5 5 5 6B GB 6B 6B 1B 18 18 19 1g 2D 24 287 13 13 13 13 18 25 28 3 0 06 a 06 10 12 15 15 OE OS 1b 1S lel |
PDF Manual |
ENGLISH |
|
11. |
DWYER INSTRUMENTS, INC. Phone: 219/879-8000
Bulletin L UL Series UL Transmitters Donya Specifications Installation and Operating Instructions DWYER INSTRUMENTS INC Phone 219 879 8000 WWW dwyer inst com P O BOX 373 MICHIGAN CITY INDIANA 46361 U S A Fax 219 872 9057 e mail info dwyer inst com Table of Contents Chapter 1 Introduction Specifications se ssa TT ETT ND NAM AA MAG oe ae eae ee eae 2 Measuring Ranges 5522cc60 KABABAAN ee thane KA Seddon d ae AEGRO RO 2 Chapter 2 Installation |
PDF Manual |
ENGLISH |
|
12. |
DWYER 475
vectus importatum ls MICROMAN METROS MODELO 475 e Nova op o para faixa de baixa press o a partir de 0 1 00 polegada coluna d gua Mede press es positivas negativas e diferenciais Caixa resistente em alum nio extrudado Leve robusto de resposta r pida e f cil de usar Dupla unidade de calibra o m trica e inglesa APLICA ES Os Man metros Digitais Port teis S rie 475 FM distribu dos pela Vectus s o ideais para calibra |
PDF Manual |
ENGLISH |
|
13. |
DWYER 1207A QUICK REFERENCE GUIDE
DWYER 1207A QUICK REFERENCE GUIDE ANALYZER FEATURES AND KEYPAD ___ Infra Red Printer Emitter lt a and Torch Light Socket for Gas Leak Detector F PO a i _ Line Select LED s lt __ Menu Controls Scroll Up Down Enter wo Particle Filter Rotary Dial __ a Water Trap Battery Charging Indicator ia a m i i Flue Gas Inlet Analyzer Connections See Diagram Overleaf PUM |
PDF Manual |
ENGLISH |
|
14. |
DWYER INSTRUMENTS, INC. Series 1950G – Integral Explosion
Set Point Adjustment Screw External Ground Screw 1 2 female NPT Electrical Conduit Connection Vent Drain 7 Captive Plug Screw The Model 1950G Explosion Proof Switch combines the best features of the popular Dwyer Series 1900 Pressure Switch with a compact explosion proof housing This unit is UL CSA FM listed for use in Class I Groups A B C D Class Il Groups E F G and Class Ill atmos pheres and Directive 94 9 EC ATEX Compliant for CE |
PDF Manual |
ENGLISH |
|
15. |
W.E. ANDERSON DIV., DWYER INSTRUMENTS, INC.
Bulletin E 78 Series H3 Differential Pressure Switches Specifications Installation and Operating Instructions COVER SET SCREW L COVER 3 4 NPT CONDUIT CONN D q 5 3 8 136 53 2 13 32 61 12 4 37 DIA MOUNTING HOLES IN MOUNTING BRACKET OPTIONAL DRAIN 76 2 1 8 NPT HIGH PRESSURE CONN 1 8 NPT LOW PRESSURE CONN Series H3 Differential Pressure Switches actuateoneor SPECIFICAT |
PDF Manual |
ENGLISH |
|
16. |
8600 - Dwyer Instruments, Inc.
INSTRUCTIONS FOR THE 8600 SERIES MICROPROCESSOR BASED TEMPERATURE PROCESS CONTROL x b m WM W0 LOVE CONTROLS DIVISION Dwyer Instruments Incorporated PO Box 338 Oo Michigan City IN 46361 0338 800 828 4588 O 219 879 8000 O FAX 219 872 9057 www love controls com December 1998 949 1277 3 CONTENTS niil zuo es ee 4 uio m 5 Wiring for Transmitter inputs eeeennmm 6 Wiring for 15 VDC Out |
PDF Manual |
ENGLISH |
|
17. |
DWYER INSTRUMENTS, INC. Phone: 219/879-8000
an o 20 39 a N aae AA sD E MASTER amp prow OUTLET se amp URE 1000 P amp MAX PRESS Tantats w pran Maica tite ine MEE sAN TE s AERIAN Saeed nd CAT NO aMV l yates Series RMV Rate Master Dial Type Flowmeters pro vide accurate dependable measurement of water flows to 20 GPM Installed in line they employ a target type ele ment linked to a flexible leaf spring which deflects in pro portion to the force |
PDF Manual |
ENGLISH |
|
18. |
DWYER INSTRUMENTS, INC. Phone: 219/879-8000
Series SSM 316 amp SSB All Metal Flowmeters are ideal for dirty or Opaque fluids high temperature and high pressure service and harsh environments The direct reading scale provides 2 accuracy Flowmeters can quickly be disassembled without removing the body from the pipeline for easy cleaning SAFETY PRECAUTIONS Personnel safety should be considered before pressurizing and operating the system There are numerous possibilities for error in system operation and maintenanc |
PDF Manual |
ENGLISH |
|
19. |
DWYER INSTRUMENTS, INC.
BFM BFS Series BFM Bulk Flow Monitor provides effective monitoring for most flow no flow conditions in pipes and chutes It s sensing techniques which use a Piezo element makes the BFM versatile for most flow no flow applications The BFM Control offers many unique advance features that exceed the industry standards The BFM Central Processing Unit monitors movement of almost anything through a pipe or chute system The BFM is ideal for sensing the presence or absence of |
PDF Manual |
ENGLISH |
|
20. |
DLI2 - Dwyer Instruments, Inc.
PRESSURE RECORDER coin LAST MEASURED reper PSIA Data Logger Manual Table of Contents Section 1 Device Safety GE ese sd ee gudd nL Ee ee 3 1 1 Model information ssssssssscccccccccccccccecceeceeeeccceeeceeeeeeeees 3 T2 SP CiHiCatiONs EO EE EE REEN 3 M3 WET DE EE EE OO EE sees 5 Section 2 Device Overview ie ER ee RR ee nno 6 Section 3 Status Indicator Icons ees sesse CLLH Y HON 7 Se Battery Status iu gies esse ige sege geed R |
PDF Manual |
ENGLISH |
|