Similar For Slant/Fin User Manuals |
---|
More Slant/Fin User Manual |
---|
# | Title | Type | Language | Download |
1. |
Slant/Fin 350 Series user manual
radiation with the convenience and economy of baseboard m 350 HIGH OUTPUT SLOPE TOP BASEBOARD Slant Fin 350 Series Ideal for light commercial and industrial hot water or steam heating Compactness and economy of baseboard High output and heavy duty construction Two heights for one or two heating element tiers Nu White enamel finish standard Interchangeable heating elements Fully assembled and factor |
PDF Manual |
ENGLISH |
|
2. |
Slant/Fin Sentry S-60 to S-150 user manual
SlantFln DIMENSIONS GAS BOILE r i SM SENTRY 3 4 to air eliminating system by others Dimensions MODEL S 34 IV2 1 Supply 28 7 i6 I L 19 3 4 LEFT END VIEW 672 FRONT VIEW 1 4 Circ Flange 1V2 Return Tapping Combination Gas Valve gas tapping 1 2 n Sediment Trap required RIGHT END VIEW LEFT END VIEW Blocked Vent 11 Safety Switch 1 4 Circ Flange 1V2 Return Tapping Combination Gas Val |
PDF Manual |
ENGLISH |
|
3. |
Slant/Fin VHS-90 user manual
User s Information Manual VICTORY II GAS BOILERS VHS MODELS VHS Models with Intermittent Pilot System Spark Ignition FOR YOUR SAFETY Before operating this boiler READ this manual DO NOT attempt to install service or repair this boiler yourself There are no user serviceable parts Contact a qualified service agency if your boiler needs repair or maintenance Ask your gas supplier for a list of qualified service agencies A qualified service agency |
PDF Manual |
ENGLISH |
|
4. |
Slant/Fin VH-180 user manual
Victory n Cast iron power vent gas boilers BOILER REPLACEMENT PARTS LIST This parts list must be left with owner hung on or adjacent to the boiler Owner should retain parts list for future reference ITEM NO DESCRIPTION VH 30 MODEL NUMBERS VH 60 VH 90 VH 120 VH 150 VH 180 1 Jacket Top Panel 440051 440052 440053 440054 440055 440056 2 Jacket Back Panel 412182 412183 412184 412185 412186 412187 3 Jacket Left Panel 440067 |
PDF Manual |
ENGLISH |
|
5. |
Slant/Fin VH-30 user manual
Victory n Cast iron power vent gas boilers BOILER REPLACEMENT PARTS LIST This parts list must be left with owner hung on or adjacent to the boiler Owner should retain parts list for future reference ITEM NO DESCRIPTION VH 30 MODEL NUMBERS VH 60 VH 90 VH 120 VH 150 VH 180 1 Jacket Top Panel 440051 440052 440053 440054 440055 440056 2 Jacket Back Panel 412182 412183 412184 412185 412186 412187 3 Jacket Left Panel 440067 |
PDF Manual |
ENGLISH |
|
6. |
Slant/Fin KC-50 user manual
S antPtn PRODIGY Gas fired Direct Vent Cast iron Hot water boilers BOILER REPLACEMENT PARTS LIST For Models KC 50 and KC 100 When ordering replacement parts specify the boiler model number serial number and gas by name natural or propane Parts are available from your local Slant Fin heating contractor wholesaler or Slant Fin Corporation Ref Description KC 50 KC 100 1 Gas Valve RS7200 Dern 660520 660520 2 Combustion Blower 651307 65 |
PDF Manual |
ENGLISH |
|
7. |
Slant/Fin SE-245 user manual
RATINGS CHART GAS BOILE SENTINEL SE SERIES Natural and L P Propane Gas MODEL NUMBER t A G A INPUT Btuh D O E CAPACITY Btuh NET l B R RATING WATER Btuh WATER Sq Ft EFFICIENCY A F U E DIMENSIONS A B c D STANDING PILOT INTERMITTENT IGNITION SE 70 70 000 58 000 50 000 333 81 5 82 0 11 17 4 45 SE 105 105 000 87 000 76 000 507 81 6 82 1 14 8 20 5 46 3 e SE 140 14 |
PDF Manual |
ENGLISH |
|
8. |
Slant/Fin B-120A user manual
Residential Gas fired Hot Water Boilers SlantlFsn User s Information Manual Bobcat Direct Vent Sealed Combustion Condensing Boiler Model B 120A and B 200A FOR YOUR SAFETY Before operating this boiler READ this manual DO NOT attempt to install service or repair this boiler yourself There are no user serviceable parts Contact a qualified service agency if your boiler needs repair or maintenance Ask your gas supplier for a list of qualified service ag |
PDF Manual |
ENGLISH |
|
9. |
Slant/Fin LDWO SERIES user manual
Modular Boiler Submittal Data Slant Fin omm LDWO SERIES Oil fired Hot Water A Caravan modular boiler system consists of two or more compact cast iron boilers that offer significant advantages in terms of installed cost efficiency and reliability Caravan systems are based on step firing just enough modules to meet hot water or space heating demands LDWO systems are available in 602 000 to multi million Btuh gross input For additional information see Caravan Engin |
PDF Manual |
ENGLISH |
|
10. |
Slant/Fin VSPH-120 user manual
This parts list must be left with owner hung on or adjacent to the boiler Owner should retain parts list for future reference Vl TftDV l CDU Cast iron W lv I JW W vu U U sealed combustion gas boilers BOILER REPLACEMENT PARTS LIST Item No DESCRIPTION VSPH 60 VSPH 90 VSPH 120 VSPH 150 VSPH 180 1 Jacket Top Panel 451053 451054 451055 451056 451057 2 Jacket Back Panel 451128 451129 451130 451131 451132 3 Jacket Left Panel 4 |
PDF Manual |
ENGLISH |
|
11. |
Slant/Fin Gas Condensation Within Boilers user manual
Flue Gas Condensation Within Boilers The following note can be found on the cover page of any of the Slant Fin boiler Installation Operation manuals IMPORTANT RADIANT FLOOR LOW WATER TEMPERATURE And LARGE WATER VOLUME systems require special piping arrangements See page Additionally the following will be included in the piping section of the manuals At a later date we plan to add suggested piping arrangements for applications such as these RADIANT FLOOR LOW |
PDF Manual |
ENGLISH |
|
12. |
Slant/Fin VSPH-150 user manual
This parts list must be left with owner hung on or adjacent to the boiler Owner should retain parts list for future reference Vl TftDV l CDU Cast iron W lv I JW W vu U U sealed combustion gas boilers BOILER REPLACEMENT PARTS LIST Item No DESCRIPTION VSPH 60 VSPH 90 VSPH 120 VSPH 150 VSPH 180 1 Jacket Top Panel 451053 451054 451055 451056 451057 2 Jacket Back Panel 451128 451129 451130 451131 451132 3 Jacket Left Panel 4 |
PDF Manual |
ENGLISH |
|
13. |
Slant/Fin CB Series user manual
SlantjFin c SIB1IS BLB 4 Gas fired Sealed Combustion I Tl I I Cast iron Hot water boilers BOILER REPLACEMENT PARTS LIST When ordering replacement parts specify the boiler model number serial number and gas by name natural or propane For replacement parts heating contractors should contact their Slant Fin boiler distributor Ref Description CB 45 CB 90 CB 135 CB 180 1 Gas Valve RS7200 Dern 660520 660520 660520 660520 2 Combustion Blo |
PDF Manual |
ENGLISH |
|
14. |
Slant/Fin GALAXY GG user manual
User s Information Manual SlantjFIn Galaxy GG GX GXH amp GXHA Series Sentry S SX Series and Sentinel SE Series Gas Boilers with Continuous Pilot FOR YOUR SAFETY Before operating this boiler READ this manual DO NOT attempt to install service or repair this boiler yourself There are no user serviceable parts Contact a qualified service agency if your boiler needs repair or maintenance Ask your gas supplier for a list of qualified service agencies WARNIN |
PDF Manual |
ENGLISH |
|
15. |
Slant/Fin Monitron EH Boilers user manual
Electric Boiler A major answer to the changing heating fuel situation HOT WATER MODELS IN 9 SIZES 8 kw 27 301 Btuh to 40 kw 136 506 Btuh Before purchasing this appliance read important energy cost and efficiency information available from your contractor Monitron Compact easy to install for new or standby installations Monitron combines the availability and dependability of electricity with the comfort and performance of conventiona |
PDF Manual |
ENGLISH |
|
16. |
Slant/Fin Hydronic Explorer 2 user manual
Slant Fin Hydronic Explorer 2 User Manual Slant Fin Corporation 100 Forest Drive Greenvale NY 11548 516 484 2600 www slantfin com PROPRIETARY INFORMATION NOTICE This document contains information proprietary to Slant Fin Corporation All rights are reserved No part of this document may be reproduced transmitted processed or recorded by any means or form electronic mechanical photographic or otherwise nor be released to any third party without the express wri |
PDF Manual |
ENGLISH |
|
17. |
Slant/Fin Sentinel SE-210 user manual
RATINGS CHART GAS BOILE SENTINEL SE SERIES Natural and L P Propane Gas MODEL NUMBER t A G A INPUT Btuh D O E CAPACITY Btuh NET l B R RATING WATER Btuh WATER Sq Ft EFFICIENCY A F U E DIMENSIONS A B c D STANDING PILOT INTERMITTENT IGNITION SE 70 70 000 58 000 50 000 333 81 5 82 0 11 17 4 45 SE 105 105 000 87 000 76 000 507 81 6 82 1 14 8 20 5 46 3 e SE 140 14 |
PDF Manual |
ENGLISH |
|
18. |
Slant/Fin GALAXYTM GG Series user manual
Hot water and steam Natural and L P PROPANE GASES _ SlantFln Galaxy Cast iron boilers Slant Fin s Galaxy is one of America s most trusted gas boilers Installed in tens of thousands of homes Galaxy is the choice of experienced heating profession als everywhere For homeowners it s the wise choice for long term efficiency and reliability Fuel saving performance with traditional cast iron boiler design Versatility to meet your home s unique h |
PDF Manual |
ENGLISH |
|
19. |
Slant/Fin GF-200 user manual
In English 1 10 En Frangaise 11 20 En Espanol 21 30 Portable Electric Warm Mist Humidifier with fan Germ Free Model GF 200 GF 200B GF 210 and GF 210W GF 200 Shown Patented Instructions for Operation Care and Cleaning Limited Warranty READ AND SAVE THESE INSTRUCTIONS Printed in CHINA 8 00 Imprime aux CHINE 8 00 Impreso en CHINA 8 00 Publication GF 200 200B 210 210W 40EFS Part Number 91 1001 16 This item has a polarized plug As |
PDF Manual |
ENGLISH |
|
20. |
Slant/Fin GF-211D user manual
JSIantjFm Portable Electric Warm Mist Humidifier with fan Germ Free Model GF 211D In English 1 11 En Frangais 12 22 En Espanol 23 32 GF 211D Shown Patented Instructions for Operation Care and Cleaning Limited Warranty READ AND SAVE THESE INSTRUCTIONS Printed in CHINA Publication GF 211 D Part Number 31IMF211190 READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE ATTEMPTING TO OPERATE YOUR HUMIDIFIER FOLLOWING THESE SIMPLE GUIDELIN |
PDF Manual |
ENGLISH |
|