Hubbell Industrial Tamper Resistant and AUTOGUARD™ Self-Test
This patented industrial design includes an exclusive tamper resistant system to protect against
objects being placed in a blade opening. Due to a unique switching technology, power is not
present if an object is inserted within an individual slot. This is significantly superior to the plastic
shutter method that is used by competition today.
The National Electric Code per article 517.18C states “Pediatric Locations, receptacles located
within rooms, bathrooms, playrooms, activity rooms and patient care areas of pediatric wards
shall be listed tamper resistant or shall employ a listed tamper resistant cover.”
This Fed Spec solution is also an excellent choice for psychiatric areas, medical facilities, heavy
industrial, prisons, day care, laboratories, elderly facilities and schools. Industrial “robust” mechanical design &
materials provide a receptacle with superior performance. This technology is also available in Hospital Grade.

Tamper Resistant GFCI

Color
Brown
Ivory
White
Gray
Black
Red

Industrial
15A
20A
GFR5262TR
GFR5362TR
GFR5262ITR
GFR5362ITR
GFR5262WTR
GFR5362WTR
GFR5262GYTR
GFR5362GYTR
GFR5262BKTR
GFR5362BKTR
GFR5262RTR
GFR5362RTR

Hospital
15A
20A
GFR8200TR
GFR8300TR
GFR8200ITR
GFR8300ITR
GFR8200WTR
GFR8300WTR
GFR8200GYTR
GFR8300GYTR
GFR8200RTR
GFR8300RTR
GFR8200BKTR
GFR8300BKTR

GFR5362ITR

AUTOGUARD™ Self Test Tamper Resistant GFCI

The best of both worlds combine to provide this exclusive industrial and hospital grade safety product.

Color
Brown
Ivory
White
Gray
Black
Red

Industrial
15A
20A
GFR5262SG
GFR5362SG
GFR5262SGI
GFR5362SGI
GFR5262SGW
GFR5362SGW
GFR5262SGGY
GFR5362SGGY
GFR5262SGBK
GFR5362SGBK
GFR5262SGR
GFR5362SGR

Hospital
15A
20A
GFR8200SG
GFR8300SG
GFR8200SGI
GFR8300SGI
GFR8200SGW
GFR8300SGW
GFR8200SGGY GFR8300SGGY
GFR8200SGBK
GFR8300SGBK
GFR8200SGR
GFR8300SGR

GFR8300ITR

GFR5362SGI

The National Electric Code per article 517.18C states “Pediatric Locations, receptacles located within rooms,
bathrooms, playrooms, activity rooms and patient care areas of pediatric wards shall be listed tamper resistant or
shall employ a listed tamper resistant cover.”

Dimensions

Specifications
Trip Level 	
Trip Time 	
Frequency 	
Voltage	
Maximum Humidity 	
Maximum Interrupting	
Capacity
Operating Temperature 	
Codes & Standards	
	
	
	
	
Terminal	
Accommodations	

4 – 6 mA
.025 sec
60Hz
120V AC +10% - 15%
95%
2,000 Amps

GFR8300SGI

-35°C to +66°C (-30°F to +150°F)
Meets 2006 UL 943 Class A GFCIs and
UL 498 for Receptacles
Complies to NEC, CEC & OSHA
UL File E-41978,
CSA File LR-24886
#14-10 AWG stranded or solid
copper conductors only.

Note: Tamper Resistant only, has a single LED located to the right of test/reset buttons.
Printed In U.S.A. Specifications subject to change without notice.  ® Registered trademark of Hubbell Incorporated

Hubbell Incorporated (Delaware) • 185 Plains Road • Milford, CT 06461-2420 • (203) 882-4800 • FAX (800) 255-1031

H5212

www.hubbell-wiring.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Modify Date                     : 2007:10:22 16:13:16+05:30
Create Date                     : 2007:10:22 16:11:14+05:30
Creator                         : Adobe InDesign CS2 (4.0.4)
Producer                        : Adobe PDF Library 7.0
Page Count                      : 1
EXIF Metadata provided by EXIF.tools

Navigation menu