GETTING
STARTED MOUNTING
INCLUDED IN THIS BOX
68-0239EF-12
APPENDICES
Tools needed to install Enhanced Air Cleaner
Standard screwdriver
Phillips screwdriver
Metal cutter
Drill
Duct Sealant
Replacement Air Filters
Filter Size (in.)
Part Number
F100 - MERV 11 F200 - MERV 13
12.5 x 20 FC100A1052 N/A
16 x 25 FC100A1029 FC200E1029
16 x 20 FC100A1003 FC200E1003
20 x 25 FC100A1037 FC200E1037
20 x 20 FC100A1011 FC200E1011
SPECIFICATIONS
Media Air
Cleaner Size (in.)
F100
Media Air Cleaner
w/ MERV 11 Filter
F200
Media Air Cleaner
w/ MERV 13 Filter
16 X 25 F100F1625 F200F1625
16 X 20 F100F1620 F200F1620
20 X 25 F100F2025 F200F2025
20 X 20 F100F2020 F200F2020
25 X 22 F100F2051 -
25 X 20 F100F2044 -
SPECIFICATIONS
•
PROFESSIONAL INSTALLATION GUIDE.
GUIDE D’INSTALLATION PROFESSIONNELLE.
Honeywell Media Air Cleaners

GETTING
STARTED
Congratulations for selecting the Honeywell Media Air Cleaner for your home comfort system! The Honeywell
position within the return air duct of any gas, oil, and electric forced warm air furnaces and to compressor
When Installing this Product...
1.
2.
3.
4.
How it Works
Application Considerations
The Honeywell Media Air Cleaner is designed to work with gas, oil, and electric forced warm air furnaces and
Models
Air Conditioning
Humidiers
UV Lights
Honeywell Media Air Cleaner 68-0239EF—12
2

GETTING
STARTED
Transitions
•
•
Turning Vanes
Sheetmetal
Offsets
If the duct connection to the furnace in a side
TURNING
VANES
M5651
M948C
LESS
THAN
7 in.
(178 mm)
OFFSET
AT LEAST
7 in.
(178 mm)
1
1 REQUIRED TURNING VANES HELP DISTRIBUTE AIRFLOW EVENLY.
20 DEGREE EXPANSION PER SIDE PER
FITTING (4 IN. PER RUNNING FOOT
[100 MM PER 300 LINEAR MM])
RETURN AIR
DUCT
TRANSITION FITTING
ELECTRONIC AIR CLEANER CABINET M947B
DUCT SIZE CHANGED GRADUALLY TO PREVENT TURBULENCE.
Honeywell Media Air Cleaner 68-0239EF—12 3

GETTING
STARTED
Personal Safety
•
•
•
Before Mounting
•
•
•
•
•
NOTE:
If Replacing an Old Air Cleaner
Failure to comply with these requirements will result in voided warranty, improper installation, and
service callbacks.
Honeywell Media Air Cleaner 68-0239EF—12
4

MOUNTING
NOTE:
M939C
M940C
Choosing a Mounting Position
where return enters side inlet of
M941A
cleaner is mounted vertically on
louvered return air opening in closet
Honeywell Media Air Cleaner 68-0239EF—12 5

MOUNTING
M942C
media air cleaner mounted
M943C
M944C
furnace, with media
air cleaner mounted
with media air cleaner mounted
M945C
M946C
Honeywell Media Air Cleaner 68-0239EF—12
6

MOUNTING
NOTE:
STEP ONE: Review the Installation Plan
STEP TWO: Fasten the Cabinet to the Furnace
STEP THREE: Install Turning Vanes
STEP FOUR: Fasten Cabinet to Ductwork
STEP FIVE: Connect Ductwork
STEP SIX: Seal Joints
STEP SEVEN: Install Filter Cartridge
Mounting the Honeywell Media Air Cleaner
Honeywell Media Air Cleaner 68-0239EF—12 7

MOUNTING
•
•
•
•
•
•
• Run the furnace or cooling system through one complete cycle to make sure the system operates as
Checkout
Maintenance
Honeywell Media Air Cleaner 68-0239EF—12

SPECIFICATIONS
F100 Specications
MERV Rating*:
Static Pressure Drop:
Efciency Denition*:
= 32%
= 72%
= 96%
0500 1000 1500 2000
0.000
0.050
0.100
0.150
0.200
0.250
0.300
12.5 X 20
16 X 20
16 X 25
20 X 20
20 X 25
FILTER SIZE
PRESSURE DROP (IN. WC)
AIRFLOW (CFM)
M34911
WHEN FIRST INSTALLED. PRESSURE DROP INCREASES AS FILTER
BECOMES LOADED. REPLACE FILTER WHEN PRESSURE DROP
REACHES 0.5 IN. WC. (0.1 kPa).
AVAILABLE ONLY IN UNITED STATES.
2
1
1
2
F200 Specications
MERV Rating*:
Static Pressure Drop:
Efciency Denition*:
= 63%
= 91%
= 99%
0500 1000 1500 200
0
0
0.1
0.2
0.3
0.4
PRESSURE DROP (IN. WC)
AIRFLOW (CFM)
M13662
WHEN FIRST INSTALLED. PRESSURE DROP INCREASES AS FILTER
BECOMES LOADED. REPLACE FILTER WHEN PRESSURE DROP
REACHES 0.5 IN. WC. (0.1 kPa).
1
1
20 x 25 in.
(508 x 635 mm)
20 x 20 in.
(508 x 508 mm)
16 x 25 in.
(406 x 635 mm)
16 x 20 in.
(406 x 508 mm)
M37054
F100F SIZE
IN.
16 X 25
16 X 20
20 X 25
20 X 20
MM
406 X 635
406 X 508
508 X 635
508 X 508
DIM. A
14-7/16
14-7/16
18-7/16
18-7/16
367
367
468
468
DIM. B
16-3/16
16-3/16
20-3/16
20-3/16
411
411
513
513
23-1/4
18-1/4
23-1/4
18-1/4
DIM. C
591
457
591
457
DIM. D
25-7/16
20-7/16
25-7/16
20-7/16
646
519
646
519
IN. MM IN. MM IN. MM IN. MM
6-3/4
(170)
1-7/16 (37)
DIM. A
(SEE
TABLE)
7/8
(22)
DIM. C (SEE TABLE)
DIM. D (SEE TABLE)
DIM.
B
(SEE
TA
BLE)
Dimensions
Temperature Rating
Approvals
Underwriters Laboratories, Inc.:
Replacement Filter Table
Filter Size (in.) Part Number
F100 F200
20 x 12-1/2 x 4-3/8 FC100A1052 N/A
16 x 24-7/8 x 4-3/8 FC100A1029 FC200E1029
16 x 19-3/4 x 4-3/8 FC100A1003 FC200E1003
20 x 24-7/8 x 4-3/8 FC100A1037 FC200E1037
20 x 19-3/4 x 4-3/8 FC100A1011 FC200E1011
Honeywell Media Air Cleaner 68-0239EF—12 9

Home and Building Technologies
Honeywell
715 Peachtree Street NE

POUR
COMMENCER MONTAGE CARACTÉRISTIQUES
TECHNIQUES
INCLUS DANS LA BOÎTE
Épurateurs d’air à fibres de Honeywell
•
PROFESSIONAL INSTALLATION GUIDE.
GUIDE D’INSTALLATION PROFESSIONNELLE.
Outils requis pour installer
l’épurateur d’air amélioré
Filtres à air de rechange
Dimension du
ltre (po)
Référence de pièce
F100 - MERV 11 F200 - MERV 13
12,5 x 20 FC100A1052 N/A
16 x 25 FC100A1029 FC200E1029
16 x 20 FC100A1003 FC200E1003
20 x 25 FC100A1037 FC200E1037
20 x 20 FC100A1011 FC200E1011
Dimension de
l’épurateur d’air
(po.)
Épurateur d’air
F100 avec ltre
MERV 11
Épurateur d’air
F200 avec ltre
MERV 13
16 X 25 F100F1625 F200F1625
16 X 20 F100F1620 F200F1620
20 X 25 F100F2025 F200F2025
20 X 20 F100F2020 F200F2020
25 X 22 F100F2051 -
25 X 20 F100F2044 -

POUR
COMMENCER
Lors de l’installation du produit...
1.
2.
3.
4.
Fonctionnement
Modèles
Climatisation
Humidicateurs
Lampes UV
Épurateur d’air à bres de Honeywell 68-0239EF—12
12

POUR
COMMENCER
Transitions
• Utiliser des transitions graduelles pour réduire les
•
100 mm tous les 300 mm linéaires [4 po par
Aubes directrices
Tôle
Déviations
dans une installation latérale alloue un espace
AUBES
DIRECTRICES
MF5651
MF948C
MOINS
DE 178 mm
(7 po)
DÉVIA
TION
AU MOINS
178 mm (7 po)
AUBES DIRECTRICES REQUISES POUR UNE DISTRIBUTION UNIFORM
E
DU DÉBIT D'AIR
1
1
EXP
ANSION DE 20° PAR CÔTÉ PAR RACCORD
(100 MM
TOUS LES 300 MM LINÉAIRES
[4 PO P
AR PIED DE LONGUEUR])
GAINE D’AIR DE RETOUR
RACCORD DE TRANSITION
ARMOIRE DE L’ÉPURATEUR D’AIR À FIBRES MF947
DIMENSION DE GAINE MODIFI
É
E GRADUELLEMENT POUR
ÉVITER LES TURBULENCES.
Épurateur d’air à bres de Honeywell 68-0239EF—12 13

POUR
COMMENCER
Sécurité personnelle
•
•
•
Avant le montage
•
•
•
•
•
REMARQUE :
Pour le remplacement d’un ancien épurateur d’air
Le non-respect de ces exigences annulera la garantie, nuira à l’installation et entraînera des appels
de service injustiés.
Épurateur d’air à bres de Honeywell 68-0239EF—12
14

MONTAGE
REMARQUE :
Sélection de la position de montage
M939C
M940C
superposé avec installation
chauffage superposé avec
M941A
superposé avec installation dans un
de chauffage entre ce dernier et
Épurateur d’air à bres de Honeywell 68-0239EF—12 15

MONTAGE
M942C
M943C
M944C
avec épurateur
la gaine de retour ou le
M945C
M946C
Épurateur d’air à bres de Honeywell 68-0239EF—12
16

MONTAGE
REMARQUE :
ÉTAPE 1 : Révision du plan d’installation
ÉTAPE 2 : Fixation de l’armoire à l’appareil de chauffage
ÉTAPE 3 : Installation des aubes directrices
ÉTAPE 4 : Fixation de l’armoire aux gaines
ÉTAPE 5 : Connexion des gaines
ÉTAPE 6 : Étanchéication des joints
ÉTAPE 7 : Installation du ltre
Épurateur d’air à bres de Honeywell 68-0239EF—12 17

MONTAGE
•
•
•
•
•
•
•
Entretien
Épurateur d’air à bres de Honeywell 68-0239EF—12

CARACTÉRISTIQUES
TECHNIQUES
MF37054
DIMENSIONS DU F100F
PO
16 X 25
16 X 20
20 X 25
20 X 20
MM
406 X 635
406 X 508
508 X 635
508 X 508
DIM. A
14-7/16
14-7/16
18-7/16
18-7/16
367
367
468
468
DIM. B
16-3/16
16-3/16
20-3/16
20-3/16
411
411
513
513
23-1/4
18-1/4
23-1/4
18-1/4
DIM. C
591
457
591
457
DIM. D
25-7/16
20-7/16
25-7/16
20-7/16
646
519
646
519
PO MM PO MM PO MM PO MM
6-3/4
(170)
1-7/16 (37)
DIM. A
(VOIR
TABLEAU)
7/8
(22)
DIM. C (VOIR TABLEAU)
DIM. D (VOIR TABLEAU)
DIM. B
(VOIR
T
ABLEAU)
Caractéristiques du F100
Valeur MERV* :
Chute de pression statique :
Cotes d’efcacité* :
= 32%
= 72%
= 96%
0500 1000 1500 2000
0.000
0.050
0.100
0.150
0.200
0.250
0.300 12.5 X 20
16 X 20
16 X 25
20 X 20
20 X 25
TAILLE DU FILTRE
CHUTE DE PRESSION (PO C.E.)
DÉBIT D’AIR (EN pi3/min)
MF34911
LORS DE LA PREMIÈRE INSTALLATION. LA CHUTE DE PRESSION AUGMENTE
À MESURE QUE LE FILTRE SE REMPLISSE. REMPLACER LE FILTRE
LORSQUE LA CHUTE DE PRESSION ATTEINT 0,5 PO C.E. (0,1 kPa).
DISPONIBLE AUX ÉTATS UNIS SEULEMENT.
2
1
1
2
Caractéristiques du F200
Valeur MERV* :
Chute de pression statique :
Cotes d’efcacité* :
= 63%
= 91%
= 99%
0500 1000 1500 2000
0
0.1
0.2
0.3
0.4
CHUTE DE PRESSION (PO C.E.)
DÉBIT D’AIR (EN pi3/min)
MF13662
LORS DE LA PREMIÈRE INSTALLATION. LA CHUTE DE PRESSION AUGMENTE
À MESURE QUE LE FILTRE SE REMPLISSE. REMPLACER LE FILTRE
LORSQUE LA CHUTE DE PRESSION ATTEINT 0,5 PO C.E. (0,1 kPa).
1
1
20 x 25 po
(508 x 635 mm)
20 x 20 po
(508 x 508 mm)
16 x 25 po
(406 x 635 mm)
16 x 20 po
(406 x 508 mm)
Dimensions
Température nominale
Homologations
Underwriters Laboratories Inc. :
Tableau des ltres de rechange
Dimension du
ltre (po)
Référence de pièce
F100 F200
20 x 12-1/2 x 4-3/8 FC100A1052 N/A
16 x 24-7/8 x 4-3/8 FC100A1029 FC200E1029
16 x 19-3/4 x 4-3/8 FC100A1003 FC200E1003
20 x 24-7/8 x 4-3/8 FC100A1037 FC200E1037
20 x 19-3/4 x 4-3/8 FC100A1011 FC200E1011
Épurateur d’air à bres de Honeywell 68-0239EF—12 19

Home and Building Technologies
Honeywell
715 Peachtree Street NE